| Brand | HELIAX® | Positive Stop™ |
| Product Type | Wireless and radiating connector |
|
|
| Interface | N Male |
| Body Style | Straight |
| Harmonized System (HS) Code | 854420 (Coaxial cable and other coaxial electric conductors) |
| Mounting Angle | Straight |
| Ordering Note | CommScope® standard product (Global) |
|
|
| Connector Impedance | 50 ohm |
| Operating Frequency Band | 0 – 8800 MHz |
| Cable Impedance | 50 ohm |
| 3rd Order IMD, typical | -116 dBm @ 910 MHz |
| 3rd Order IMD Test Method | Two +43 dBm carriers |
| RF Operating Voltage, maximum (vrms) | 707.00 V |
| dc Test Voltage | 2000 V |
| Outer Contact Resistance, maximum | 0.30 mOhm |
| Inner Contact Resistance, maximum | 2.00 mOhm |
| Insulation Resistance, minimum | 5000 MOhm |
| Average Power | 0.6 kW @ 900 MHz |
| Peak Power, maximum | 10.00 kW |
Insertion Loss, typical  | 0.05 dB |
| Shielding Effectiveness | -130 dB |
|
|
Click on image below to enlarge.
 |
| |
|
|
| Outer Contact Attachment Method | Ring-flare |
| Inner Contact Attachment Method | Captivated |
| Outer Contact Plating | Trimetal |
| Inner Contact Plating | Silver |
| Attachment Durability | 25 cycles |
| Interface Durability | 500 cycles |
| Interface Durability Method | IEC 61169-16:9.5 |
| Connector Retention Tensile Force | 890 N | 200 lbf |
| Connector Retention Torque | 5.42 N-m | 48.00 in lb |
| Insertion Force | 66.72 N | 15.00 lbf |
| Insertion Force Method | MIL-C-39012C-3.12, 4.6.9 |
| Coupling Nut Proof Torque | 4.52 N-m | 40.00 in lb |
| Coupling Nut Retention Force | 444.82 N | 100.00 lbf |
| Coupling Nut Retention Force Method | MIL-C-39012C-3.25, 4.6.22 |
|
|
| Nominal Size | 1/2 in |
| Diameter | 22.35 mm | 0.88 in |
| Length | 76.70 mm | 3.02 in |
| Weight | 94.71 g | 0.21 lb |
|
|
| Operating Temperature | -55 °C to +85 °C (-67 °F to +185 °F) |
| Storage Temperature | -55 °C to +85 °C (-67 °F to +185 °F) |
Immersion Depth  | 1 m |
| Immersion Test Mating | Unmated |
| Immersion Test Method | IEC 60529:2001, IP68 |
| Water Jetting Test Mating | Unmated |
| Water Jetting Test Method | IEC 60529:2001, IP66 |
| Moisture Resistance Test Method | MIL-STD-202F, Method 106F |
| Mechanical Shock Test Method | MIL-STD-202, Method 213, Test Condition I |
| Thermal Shock Test Method | MIL-STD-202F, Method 107G, Test Condition A-1, Low Temperature -55 °C |
| Vibration Test Method | IEC 60068-2-6 |
| Corrosion Test Method | MIL-STD-1344A, Method 1001.1, Test Condition A |